Appendix B: Standards referred to

  1. Standards

    Standards

    BS EN 1991-1-1 Eurocode 1. Actions on structures. General actions. Densities, self-weight, imposed loads for buildings [2002] National Annex to BS EN 1991-1-1 UK National Annex to Eurocode 1. Actions on structures. General actions. Densities, self-weight, imposed loads for buildings [2002] BS 4211 Specification for permanently fixed ladders [2005 + AMD A1, Corrigenda C1, C2] BS 5395-2 Code of practice for the design of helical and spiral stairs [1984 + AMD 6076, Corrigenda July 2008, C2, C3] BS 5395-3 Code of practice for the design of industrial type stairs, permanent ladders and walkways [1985 + AMD 14247] BS 6180 Barriers in and about buildings. Code of practice [2011] BS 6206 Specification for impact performance requirements for flat safety glass and safety plastics for use in buildings [1981 + AMDs 4580, 5189, 7589, 8156, 8693] PD 6688-1-1 Recommendations for the design of structures to BS EN 1991-1-1 [2011] BS 8213-1 Windows doors and rooflights. Design for safety in use and during cleaning of windows, including door-height windows and roof windows. Code of practice [2004] BS EN 12600 Glass in building – Pendulum test – Impact test method and classification for flat glass [2002 + incorporating corrigendum April 2010]

    • Diagram 1.1 Measuring rise and going Part K Diagram 1.1 Measuring rise and going Part K (Risers and Goings)
    • [caption id="attachment_8489" align="alignnone" width="935"]Diagram 1.2 Examples of suitable tread profiles Diagram 1.2 Examples of suitable tread profiles Part K

    • Diagram 1.3 Minimum headroom Part K Diagram 1.3 Minimum headroom Part K
    • Diagram 1.4 reduced headroom for loft conversions Part K Diagram 1.4 reduced headroom for loft conversions Part K
    • Diagram 1.5 dividing flights Part K Diagram 1.5 dividing flights Part K
    • Diagram 1.6 Change of direction in flights Part K Diagram 1.6 Change of direction in flights Part K
    • Diagram 1.7 Cupboard onto landing Part K Diagram 1.7 Cupboard onto landing Part K
    • Diagram 1.8 Landings next to doors in dwellings Part K Diagram 1.8 Landings next to doors in dwellings Part K
    • Diagram 1.9 Measuring tapered treads Part K Diagram 1.9 Measuring tapered treads Part K
    • Diagram 1.10 Alternating tread stair Part K Diagram 1.10 Alternating tread stair Part K
    • Diagram 1.11 Key dimensions for handrails for common stairs in blocks of flats Part K Diagram 1.11 Key dimensions for handrails for common stairs in blocks of flats Part K
    • Diagram 1.12 Key dimensions for handrails for stairs in buildings other than dwellings Part K Diagram 1.12 Key dimensions for handrails for stairs in buildings other than dwellings Part K
    • Diagram 1.13 Handrail design Part K Diagram 1.13 Handrail design Part K
    • Diagram 2.1 Relationship of ramp gradient to the going of a flight Part K Diagram 2.1 Relationship of ramp gradient to the going of a flight Part K
    • Diagram 2.2 ramp design Part K Diagram 2.2 ramp design Part K
    • Diagram 3.1 Guarding design Diagram 3.1 Guarding design
    • Diagram 3.2 Typical Locations for guarding Part K Diagram 3.2 Typical Locations for guarding Part K
    • Diagram 4.1 Barrier siting Part K Diagram 4.1 Barrier siting Part K
    • Diagram 4.2 barrier design Part K Diagram 4.2 barrier design Part K
    • Diagram 4.3 Loading bay Part K Diagram 4.3 Loading bay Part K
    • Diagram 5.1 Critical glazing locations in internal and external walls Part K Diagram 5.1 Critical glazing locations in internal and external walls Part K
    • Diagram 5.2 Annealed glass thickness and dimension limits Diagram 5.2 Annealed glass thickness and dimension limits Part K
    • Diagram 5.4 Permanent screen protection Part K Diagram 5.4 Permanent screen protection Part K
    • Diagram 6.1 Marking by a barrier Part K Diagram 6.1 Marking by a barrier Part K
    • Diagram 6.2 Marking by a surface Part K Diagram 6.2 Marking by a surface Part K
    • Diagram 7.1 Examples of door height glazing not warranting manifestation Part K Diagram 7.1 Examples of door height glazing not warranting manifestation Part K
    • [caption id="attachment_8468" align="alignnone" width="933"]Diagram 7.2 Height of manifestation for glass doors and glazed screens Part K Diagram 7.2 Height of manifestation for glass doors and glazed screens Part K[/caption]

    • Diagram 8.1 Height of controls Part K Diagram 8.1 Height of controls Part K
    • Diagram 9.1 Safe reaches for cleaning Part K Diagram 9.1 Safe reaches for cleaning Part K
    • Diagram 9.2 Ladders a maximum of 6m long Part K Diagram 9.2 Ladders a maximum of 6m long Part K
    • Diagram 9.3 Ladders a maximum of 9m long Diagram 9.3 Ladders a maximum of 9m long
    • Diagram 10.1 Visibility requirements of doors Part K Diagram 10.1 Visibility requirements of doors Part K
    • Diagram 10.2 Avoiding doors on acces routes Part K Diagram 10.2 Avoiding doors on access routes Part K
    • Table 1.1 Rise and Going Part K Table 1.1 Rise and Going Part K risers and goings