• Diagram 1.1 Measuring rise and going Part K Diagram 1.1 Measuring rise and going Part K (Risers and Goings)
  • [caption id="attachment_8489" align="alignnone" width="935"]Diagram 1.2 Examples of suitable tread profiles Diagram 1.2 Examples of suitable tread profiles Part K

  • Diagram 1.3 Minimum headroom Part K Diagram 1.3 Minimum headroom Part K
  • Diagram 1.4 reduced headroom for loft conversions Part K Diagram 1.4 reduced headroom for loft conversions Part K
  • Diagram 1.5 dividing flights Part K Diagram 1.5 dividing flights Part K
  • Diagram 1.6 Change of direction in flights Part K Diagram 1.6 Change of direction in flights Part K
  • Diagram 1.7 Cupboard onto landing Part K Diagram 1.7 Cupboard onto landing Part K
  • Diagram 1.8 Landings next to doors in dwellings Part K Diagram 1.8 Landings next to doors in dwellings Part K
  • Diagram 1.9 Measuring tapered treads Part K Diagram 1.9 Measuring tapered treads Part K
  • Diagram 1.10 Alternating tread stair Part K Diagram 1.10 Alternating tread stair Part K
  • Diagram 1.11 Key dimensions for handrails for common stairs in blocks of flats Part K Diagram 1.11 Key dimensions for handrails for common stairs in blocks of flats Part K
  • Diagram 1.12 Key dimensions for handrails for stairs in buildings other than dwellings Part K Diagram 1.12 Key dimensions for handrails for stairs in buildings other than dwellings Part K
  • Diagram 1.13 Handrail design Part K Diagram 1.13 Handrail design Part K
  • Diagram 2.1 Relationship of ramp gradient to the going of a flight Part K Diagram 2.1 Relationship of ramp gradient to the going of a flight Part K
  • Diagram 2.2 ramp design Part K Diagram 2.2 ramp design Part K
  • Diagram 3.1 Guarding design Diagram 3.1 Guarding design
  • Diagram 3.2 Typical Locations for guarding Part K Diagram 3.2 Typical Locations for guarding Part K
  • Diagram 4.1 Barrier siting Part K Diagram 4.1 Barrier siting Part K
  • Diagram 4.2 barrier design Part K Diagram 4.2 barrier design Part K
  • Diagram 4.3 Loading bay Part K Diagram 4.3 Loading bay Part K
  • Diagram 5.1 Critical glazing locations in internal and external walls Part K Diagram 5.1 Critical glazing locations in internal and external walls Part K
  • Diagram 5.2 Annealed glass thickness and dimension limits Diagram 5.2 Annealed glass thickness and dimension limits Part K
  • Diagram 5.4 Permanent screen protection Part K Diagram 5.4 Permanent screen protection Part K
  • Diagram 6.1 Marking by a barrier Part K Diagram 6.1 Marking by a barrier Part K
  • Diagram 6.2 Marking by a surface Part K Diagram 6.2 Marking by a surface Part K
  • Diagram 7.1 Examples of door height glazing not warranting manifestation Part K Diagram 7.1 Examples of door height glazing not warranting manifestation Part K
  • [caption id="attachment_8468" align="alignnone" width="933"]Diagram 7.2 Height of manifestation for glass doors and glazed screens Part K Diagram 7.2 Height of manifestation for glass doors and glazed screens Part K[/caption]

  • Diagram 8.1 Height of controls Part K Diagram 8.1 Height of controls Part K
  • Diagram 9.1 Safe reaches for cleaning Part K Diagram 9.1 Safe reaches for cleaning Part K
  • Diagram 9.2 Ladders a maximum of 6m long Part K Diagram 9.2 Ladders a maximum of 6m long Part K
  • Diagram 9.3 Ladders a maximum of 9m long Diagram 9.3 Ladders a maximum of 9m long
  • Diagram 10.1 Visibility requirements of doors Part K Diagram 10.1 Visibility requirements of doors Part K
  • Diagram 10.2 Avoiding doors on acces routes Part K Diagram 10.2 Avoiding doors on access routes Part K
  • Table 1.1 Rise and Going Part K Table 1.1 Rise and Going Part K risers and goings